Feature :

Capacity range:
1 phase 200V-0.2~2.2kW
3 phase 200V-0.4~15kW
3 phase 400V-0.4~15kW
3 phase 600V-0.75~15kW
1 phase 200V-0.2~2.2kW (IP54)
3 phase 400V-0.75~3.7kW (IP54)

– Standard specificaitons –
3-phase 240V

 

Item Specification
Input voltage class 3-phase 240V
Applicable motor (kW) 0.4 0.55 0.75 1.5 2.2 4.0 5.5 7.5 11 15
Rating Type VFS11-
Form 2004PM 2005PM 2007PM 2015PM 2022PM 2037PM 2055PM 2075PM 2110PM 2150PM
Capacity (kVA) Note 1) 1.3 1.4 1.8 3.0 4.2 6.7 10 13 21 25
Rated output current (A) Note 2) 3.3
(3.3)
3.7
(3.3)
4.8
(4.4)
8.0
(7.9)
11.0
(10.0)
17.5
(16.4)
27.5
(25.0)
33
(33)
54
(49)
66
(60)
Output voltage Note 3) 3-phase 200V to 240V
Overload current rating 150%-60 seconds, 200%-0.5 second Note 4)
Power supply Voltage-frequency 3-phase 200V to 240V – 50/60Hz
Allowable fluctuation Voltage + 10%, -15% Note 5), frequency +/-5%
Protective method IP20 Enclosed type (JEM1030)
Cooling method Self-cooling Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter Basic filter Note 7)

 

 

3-phase 500V

Item Specification
Input voltage class 3-phase 500V
Applicable motor (kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15
Rating Type VFS11-
Form 4004PL 4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL
Capacity (kVA) Note 1) 1.1 1.8 3.1 4.2 7.2 11 13 21 25
Rated output current (A) Note 2) 1.5
(1.5)
2.3
(2.1)
4.1
(3.7)
5.5
(5.0)
9.5
(8.6)
14.3
(13.0)
17.0
(17.0)
27.7
(25.0)
33
(30)
Output voltage Note 3) 3-phase 380V to 500V
Overload current rating 150%-60 seconds, 200% -0.5 second Note 4)
Power supply Voltage-frequency 3-phase 380V to 500V – 50/60Hz
Allowable fluctuation Voltage + 10%, -15% Note 5), frequency +/-5%
Protective method IP20 Enclosed type (JEM1030)
Cooling method Forced air-cooled
Color Munsel 5Y-8/0.5
Built-in filter High-attenuation EMI filter Note 8)

 

1-phase 240V, 3-phase 600V

Item Specification
Input voltage class 1-phase 240V 3-phase 600V Note 6)
Applicable motor (kW) 0.2 0.4 0.75 1.5 2.2 0.75 1.5 2.2 4.0 5.5 7.5 11 15
Rating Type VFS11S- VFS11
Form 2002PL 2004PL 2007PL 2015PL 2022PL 6007P 6015P 6022P 6037P 6055P 6075P 6110P 6150P
Capacity (kVA) Note 1) 0.6 1.3 1.8 3.0 4.2 1.7 2.7 3.9 6.1 9.0 11 17 22
Rated output current
(A) Note 2)
1.5 (1.5) 3.3 (3.3) 4.8 (4.4) 8.0 (7.9) 11.0 (10.0) 1.7 (1.5) 2.7 (2.4) 3.9 (3.5) 6.1 (5.5) 9.0 (8.1) 11.0 (9.9) 17.0 (15.3) 22.0 (19.8)
Output voltage Note 3) 3-phase 200V to 240V 3-phase 525V to 600V
Overload current rating 150%-60 seconds, 200%-0.5 second Note 4) 150%-60 seconds, 200%-0.5 second Note 4)
Power supply Voltage-frequency 1-phase 200V to 240V . 50/60Hz 3-phase 525V to 600V . 50/60Hz
Allowable fluctuation Voltage + 10%, -15% Note 5), frequency+/-5% Voltage + 10%, -15% Note 5), frequency+/-5%
Protective method IP20 Enclosed type (JEM1030) IP20 Enclosed type (JEM1030)
Cooling method Self-cooling Forced air-cooled Forced air-cooled
Color Munsel 5Y-8/0.5 Munsel 5Y-8/0.5
Built-in filter High-attenuation EMI filter Note 8) No filter

 

Note 1. Capacity is calculated at 220V for the 240V class, at 440V for the 500V class and at 575V for the 600V models.
Note 2. Indicates rated output current setting when the PWM carrier frequency (parameter F300) is 4kHz or less. When exceeding 4kHz, the rated output current setting is indicated in the parenthesis. When the input power voltage of the 500V class model exceeds 480V, it is necessary to further reduce the setting. The default setting of the PWM carrier Frequency is 12kHz.
Note 3. Maximum output voltage is the same as the input voltage.
Note 4. May differ according to voltage and model.
Note 5. +/-10% when the inverter is used continuously (load of 100%).
Note 6. If you are using 600V model, be sure to connect an input reactor (ACL).
Note 7. Built-in standard filter: Core and capacitors, with RFI noise filter option: Complies IEC61800-3 categoly C2 (Max.5m*) and IEC61800-3 categoly C1 (Max.1m*) * Length of motor connecting cable.
Note 8. Built-in high-attenuation EMI filter: Complies IEC61800-3 categoly C2 for 240V class 0.2-1.5kW and 500V class 0.4-4.0kW, IEC61800-3 categoly C3 for 240V class 2.2kW and 500V class 5.5-15kW (Max.5m*) With RFI noise filter option : Complies IEC61800-3 categoly CI (Max.20m*) and IEC61800-3 categoly C2 (Max.50m*)* Length of motor connecting cable.
Note 9. Above 40 degreeC : Remove the protective seal from the top of the inverter. Above 50 degreeC: Remove the seal from the top of the inverter and use the inverter with the rated output current reduced.
Note 10. If inverters are installed side by side (with no sufficient space left between them) installation: Remove the seal from the top of each inverter. When installing the inverter where the ambient temperature will rise above 40 degreeC, remove the seal from the top of the inverter and use the inverter with the rated output current reduced.


Totally-Enclosed Box Type Inverter: IP54

Item Specification
Input voltage class 1-phase 240V class/3-phase 240V class/3-phase 500V class
Applicable motor (kW) 0.2 0.4 0.75 1.5 2.2 4.0
Model Voltage class Model number VFS11S/VFS11
1-phase 240V class VFS11S- 2002PLE 2004PLE 2007PLE 2015PLE 2022PLE
3-phase 240V class VFS11- 2004PME 2007PME 2015PME 2022PME 2037PME
3-phase 500V class VFS11- 4007PLE 4015PLE 4022PLE 4037PLE
Rating Capacity (kVA) Note 1: 0.6 1.3 1.8 3.0/3.0/3.1 4.2 6.7/7.2
Output current (A) Note 2: 1-phase 240V 1.5 (1.5) 3.3 (3.3) 4.8 (4.4) 8.0 (7.9) 11.0 (10.0)
3-phase 240V 3.3 (3.3) 4.8 (4.4) 8.0 (7.9) 11.0 (10.0) 17.5 (16.4)
3-phase 500V 2.3 (2.1) 4.1 (3.7) 5.5 (5.0) 9.5 (8.6)
Output voltage Note 3: 240V class: 3-phase 200 to 240V, 500V class: 3-phase 380 to 500V
Overload current rating 150%-1min., 200%-0.5 sec. (50%-reduction value)
Power supply Voltage-frequency 240V class: 1-phase/3-phase 200 to 240V-50/60Hz, 500V class: 3-phase 380 to 500V-50/60Hz
Allowable fluctuation Voltage+10%, -15% Note 4:, Frequency+/-5%
Protective method Totally enclosed type (JEM1030) compliant with IP54/possible to bring into compliance with IP55 Note 5:
Cooling method Self-cooled (with a built-in cooling fan. 1-phase/3-phase 240V-0.75kW or smaller: Cooling fan not provided)
Color Munsel 5Y-8/0.5
Built-in filter 1-phase & 500V class: High-attenuation EMI filter, 3-phase 240V class: Standard filter
Environments Use environments Indoor type. Altitude: Not more than 1000m.
Place free from corrosive and explosive gases
Ambient temperature -10 to +40 degree
Storage temperature -25 to +70 degree
Relative humidity 20 to 93%
Vibration 5.9m/s2 or less (10 to 55Hz)

 

Note 1: Capacity is calculated at 220V for the 240V models and at 440V for the 500V models.
Note 2: Indicates rated output current setting when the PWM carrier frequency (parameter F300) is 4kHz or less. The values between parentheses refer to output currents at PWM carrier frequencies of over 4kHz. They need to be reduced further at frequencies over 12kHz (If a motor cable over 30m in length is used, it is necessary to reduce them more. This means that the lives of the internal components will be shortened). When the input power voltage of the 500V class model exceeds 480V, it is necessary to further reduce the setting. The default setting of the PWM carrier frequency is 12kHz.
Note 3: The maximum output voltage is equal to the input supply voltage.
Note 4: +/-10% when the inverter is operated continuously (under a load of 100%).
Note 5: IP54-compliant structures refer to structures that protect the contents from dust and harmful effects of water that drops from every direction. The inverter can be brought into compliance with IP55 specifications by making the wiring port watertight. (IP55-compliant structures refer to structures that protect the contents from dust and harmful effects of water that comes in a jet from every direction.) To bring the inverter into compliance with IP-55, use PG screw type cable grounds. Among cable grounds available are skin-top grounds manufactured by LAPP (Germany).
Note 6: For control specifications, parameters and functions, refer to the instruction manual.
Note 7: The factory default settings of parameters are different from those of the VFS-11 standard type.
Note 8: The inverter has a built-in cooling fan. The cooling fan has a useful life of approximately 30,000 hours (2 to 3 years when operated continuously), so it needs to be replaced periodically. (Single/three-phase 240V-0.75kW models and smaller are not equipped with cooling fans.) If the cooling fan does not operate normally, the temperatures of the internal electrical components will rise high, and as a result their lives will be shortened. So inspect it periodically.
Note 9: The manual power ON-OFF switch has a useful life of approximately 5 years (if operated 12 hours per day at an average yearly ambient temperature of 30 degreeC), so it needs to be replaced periodically.

Reviews

There are no reviews yet.

Be the first to review “Inverter Toshiba | VF-S11”

Your email address will not be published. Required fields are marked *